Hermetic has set standard in pump technology with their newly developed single-stage standardised chemical canned motor pump in the HCN/HCNF range.
The HCN range is designed for aggressive, inflammable, toxic, and highly volatile liquids, solvents or other substances. The HCNF range is used for liquid gases, for example ammonia, Freon, propane, carbon dioxide, etc.
The most recent development is a single-stage standardised chemical canned motor pump in accordance with EN 22858 / ISO 2858. The area of application for liquids covers a temperature range from –120 to +120 °C. Pump performance lies between 6 and 41 kW, with a maximum flow rate of 230 m3/h and a maximum head of 140 m.
One of the special design features is an integrated monitoring system for the rotation direction (ROMi) which is firmly moulded in the terminal box. A thermistor (KL180) secured in the winding guarantees efficient protection of the motor. In addition, Hermetic provides a temperature monitoring unit using a T30 thermostat or PT100.
Online-Info www.cpp-net.com/2110455
Share: